ABAP Select data from SAP table COD_S_MP into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP COD_S_MP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to COD_S_MP.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the COD_S_MP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_COD_S_MP TYPE STANDARD TABLE OF COD_S_MP,
WA_COD_S_MP TYPE COD_S_MP,
GD_STR TYPE STRING.
DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.
FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <COD_S_MP> TYPE COD_S_MP.
*Original SAP ECC Select statement
SELECT *
*restrict ABAP select to first 10 rows
UP TO 10 ROWS
FROM COD_S_MP
INTO TABLE IT_COD_S_MP.
*Select data and declare internal table using in-line method @DATA
SELECT *
FROM COD_S_MP
INTO TABLE @DATA(IT_COD_S_MP2).
*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_COD_S_MP INDEX 1 INTO DATA(WA_COD_S_MP2).
*Latest ABAP cloud SELECT statement using the FIELDS syntax. But note to following the clean core principles you should not select directly from an SAP table
* and should instead use a CDS view or create you own CDS and use that.
SELECT FROM COD_S_MP
FIELDS *
* WHERE would go here
INTO TABLE @DATA(IT_COD_S_MP2).
*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_COD_S_MP ASSIGNING <COD_S_MP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer<COD_S_MP>-MANDT = 1.
<COD_S_MP>-POINT = 1.
<COD_S_MP>-MPOBJ = 1.
<COD_S_MP>-PSORT = 1.
<COD_S_MP>-PSORTR = 1.
ENDLOOP. LOOP AT IT_COD_S_MP INTO WA_COD_S_MP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_COD_S_MP-PTTXT, sy-vline,
WA_COD_S_MP-MLANG, sy-vline,
WA_COD_S_MP-KZLTX, sy-vline,
WA_COD_S_MP-MPTYP, sy-vline,
WA_COD_S_MP-IRFMP, sy-vline,
WA_COD_S_MP-ERDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_COD_S_MP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_COD_S_MP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_COD_S_MP INTO WA_COD_S_MP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field POINT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_COD_S_MP-POINT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COD_S_MP-POINT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ISOLA, internal->external for field MLANG CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_COD_S_MP-MLANG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COD_S_MP-MLANG.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field LOCAS CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_COD_S_MP-LOCAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COD_S_MP-LOCAS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field REFMP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_COD_S_MP-REFMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COD_S_MP-REFMP.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ATINN, internal->external for field ATINN CALL FUNCTION 'CONVERSION_EXIT_ATINN_OUTPUT' EXPORTING input = WA_COD_S_MP-ATINN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COD_S_MP-ATINN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field MRNGU CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_COD_S_MP-MRNGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COD_S_MP-MRNGU.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field TRANS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_COD_S_MP-TRANS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COD_S_MP-TRANS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UPR_DSP_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_COD_S_MP-UPR_DSP_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COD_S_MP-UPR_DSP_UNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field LOWR_DSP_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_COD_S_MP-LOWR_DSP_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COD_S_MP-LOWR_DSP_UNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_COD_S_MP-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COD_S_MP-LOGSYS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field MSEHI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_COD_S_MP-MSEHI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COD_S_MP-MSEHI.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field UPR_DSP_VAL_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_COD_S_MP-UPR_DSP_VAL_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COD_S_MP-UPR_DSP_VAL_UNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field LOWR_DSP_VAL_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_COD_S_MP-LOWR_DSP_VAL_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_COD_S_MP-LOWR_DSP_VAL_UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM.
