ABAP Select data from SAP table CINSPLOTMNG into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CINSPLOTMNG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CINSPLOTMNG.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CINSPLOTMNG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CINSPLOTMNG TYPE STANDARD TABLE OF CINSPLOTMNG,
WA_CINSPLOTMNG TYPE CINSPLOTMNG,
GD_STR TYPE STRING.
DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.
FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CINSPLOTMNG> TYPE CINSPLOTMNG.
*Original SAP ECC Select statement
SELECT *
*restrict ABAP select to first 10 rows
UP TO 10 ROWS
FROM CINSPLOTMNG
INTO TABLE IT_CINSPLOTMNG.
*Select data and declare internal table using in-line method @DATA
SELECT *
FROM CINSPLOTMNG
INTO TABLE @DATA(IT_CINSPLOTMNG2).
*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CINSPLOTMNG INDEX 1 INTO DATA(WA_CINSPLOTMNG2).
*Latest ABAP cloud SELECT statement using the FIELDS syntax. But note to following the clean core principles you should not select directly from an SAP table
* and should instead use a CDS view or create you own CDS and use that.
SELECT FROM CINSPLOTMNG
FIELDS *
* WHERE would go here
INTO TABLE @DATA(IT_CINSPLOTMNG2).
*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CINSPLOTMNG ASSIGNING <CINSPLOTMNG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer<CINSPLOTMNG>-MANDT = 1.
<CINSPLOTMNG>-INSPECTIONLOT = 1.
<CINSPLOTMNG>-STATUSPROFILE = 1.
<CINSPLOTMNG>-STATUSSHORTNAME = 1.
<CINSPLOTMNG>-STATUSCODE = 1.
ENDLOOP. LOOP AT IT_CINSPLOTMNG INTO WA_CINSPLOTMNG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_CINSPLOTMNG-INSPECTIONLOTORIGIN, sy-vline,
WA_CINSPLOTMNG-INSPECTIONLOTORIGINTEXT, sy-vline,
WA_CINSPLOTMNG-PLANT, sy-vline,
WA_CINSPLOTMNG-MATERIAL, sy-vline,
WA_CINSPLOTMNG-INSPECTIONLOTAPPROVALTEXT, sy-vline,
WA_CINSPLOTMNG-INSPECTIONLOTAPPROVAL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CINSPLOTMNG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CINSPLOTMNG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CINSPLOTMNG INTO WA_CINSPLOTMNG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field INSPECTIONLOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-INSPECTIONLOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-INSPECTIONLOT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-MATERIAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ABPSP, internal->external for field SALESORDSTOCKWBSELEMENT CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-SALESORDSTOCKWBSELEMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-SALESORDSTOCKWBSELEMENT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field INVENTORYSPCLSTKSALESDOCUMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-INVENTORYSPCLSTKSALESDOCUMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-INVENTORYSPCLSTKSALESDOCUMENT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field QUALITYCOSTCOLLECTOR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-QUALITYCOSTCOLLECTOR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-QUALITYCOSTCOLLECTOR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field COSTCENTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-COSTCENTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-COSTCENTER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PROFITCENTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-PROFITCENTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-PROFITCENTER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GJAHR, internal->external for field MATERIALDOCUMENTYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-MATERIALDOCUMENTYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-MATERIALDOCUMENTYEAR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field MATERIALDOCUMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-MATERIALDOCUMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-MATERIALDOCUMENT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SUPPLIER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-SUPPLIER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-SUPPLIER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field MANUFACTURER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-MANUFACTURER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-MANUFACTURER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MANUFACTURERPARTNMBR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-MANUFACTURERPARTNMBR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-MANUFACTURERPARTNMBR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PURCHASINGDOCUMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-PURCHASINGDOCUMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-PURCHASINGDOCUMENT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SALESOPERATIONSPLANNINGORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-SALESOPERATIONSPLANNINGORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-SALESOPERATIONSPLANNINGORDER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field MANUFACTURINGORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-MANUFACTURINGORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-MANUFACTURINGORDER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field CUSTOMER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-CUSTOMER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-CUSTOMER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SALESORDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-SALESORDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-SALESORDER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DELIVERYDOCUMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-DELIVERYDOCUMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-DELIVERYDOCUMENT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SOLDTOPARTY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-SOLDTOPARTY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-SOLDTOPARTY.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field EQUIPMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-EQUIPMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-EQUIPMENT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TPLNR, internal->external for field FUNCTIONALLOCATION CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-FUNCTIONALLOCATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-FUNCTIONALLOCATION.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field INSPLOTSELECTIONMATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-INSPLOTSELECTIONMATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-INSPLOTSELECTIONMATERIAL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit NUMCV, internal->external for field MATERIALREVISIONLEVEL CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-MATERIALREVISIONLEVEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-MATERIALREVISIONLEVEL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field INSPECTIONLOTQUANTITYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-INSPECTIONLOTQUANTITYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-INSPECTIONLOTQUANTITYUNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field INSPECTIONLOTCONTAINERUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-INSPECTIONLOTCONTAINERUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-INSPECTIONLOTCONTAINERUNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field INSPECTIONLOTSAMPLEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-INSPECTIONLOTSAMPLEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-INSPECTIONLOTSAMPLEUNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field INSPLOTMATERIALPOSTEDTO CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-INSPLOTMATERIALPOSTEDTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-INSPLOTMATERIALPOSTEDTO.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GERNR, internal->external for field SERIALNUMBER CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_CINSPLOTMNG-SERIALNUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CINSPLOTMNG-SERIALNUMBER.
WRITE:/ 'New Value:', ld_input.
ENDFORM.